Techorium Computing, Eastern Canada distributor for NTI KVM Switches

2-Outlet Remote Power Reboot Switch

control power on off reboot IP CAT5 Web

Return home

Secure Remote Power Reboot Switch with Environmental Monitoring

Securely control power on/off/reboot to a server, router, web cam, firewall or other remote device over IP.

Also known as: secure remote reboot CAT5, Web remote power, remote power switch, remote reboot over ip, control power on off IP
·Linux Inside



Additional Product Information

View Data Sheet Data Sheet (PDF): 2-Port
View Data Sheet Data Sheet (PDF): 4- and 8-Port
Secure Remote Power Reboot Switch
IPDU-S2 (Front and Back)


RoHS Compliant Remote Power Reboot Switch

Features & Applications

The ENVIROMUX® Secure Remote Power Reboot Switch allows you to remotely reboot and control power (on/off) to up to eight servers or other powered devices from any location via secure web interface, RS232, SSH, or Telnet.
  • Supports Power On or Off in addition to Reboot.
  • Three operating modes for power:
    • Manual reboot — select the outlet and turn the power on or off.
    • Scheduled reboot — set a date, time, and duration of the power cycle. Power cycles can also be scheduled as recurring daily, weekly, or monthly.
    • Associated reboot — power on or off a device when a sensor goes out of range of a user-defined threshold, or reboot if an IP device is unresponsive.
  • Security: HTTPS, SSHv2, SSLv3, IP Filtering, LDAPv3, AES 256-bit encryption, 16-character username/password authentication, user account restricted access rights.
  • Power Up Sequencing limits in-rush current.
  • Outlets can be individually named (up to 80 characters).
  • Operates on a hardened Linux system.
  • Circuit breaker protection.
  • Monitor (ping) up to 8 IP network devices.
    • Configure the timeout and number of retries to classify a device as unresponsive.
    • Power cycle associated power outlets if devices are not responding.
    • Alerts are sent if devices are not responding.
  • Monitor environmental conditions.
    • Supports two sensors, including: temperature, humidity, and water detection.
    • When a sensor goes out of range of a configurable threshold, the system will notify you via email, syslog, LEDs, web page, and network management (SNMP).
    • Powers up or down devices when sensors go out of range of user-defined thresholds.
  • Firmware upgradeable "in-field" through console port or Ethernet.

Specifications

Power
  • 90 to 250 VAC at 50 to 60 Hz.
  • Input Connector:
    • 2-Port: IEC C14 inlet.
    • 4/8 Port: IEC C20 inlet.
  • Output Connectors: IEC C13 outlets.
  • Includes line cord and output cord.
  • Outlet fuse protection.

    Current Rating

    NTI Part # In Out
    IPDU-S2 15 10
    IPDU-S4/8 20 15
RJ45 Sensor Ports
  • Two RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, and liquid detection sensors.
  • Available sensors
Network Interface
  • One 10/100 Base-T Ethernet port with RJ45 Ethernet connector.
Console Port
  • One female RJ45 port for terminal access.
Environmental
  • Operating temperature: 32°F to 122°F (0°C to 50°C).
  • Storage temperature: -13°F to 149°F (-25°C to 65°C).
  • Operating and Storage Relative Humidity: 0 to 90% non-condensing RH.
Protocols
  • HTTPS, SSHv2, SSLv3, LDAPv3, AES 256-bit encryption, SNMPv2c.
  • Operates and configures via HTTP/HTTPS web page, Telnet, SSH, or RS232 interface.
  • Alerts are sent using email, syslog, and/or SNMP traps when devices are not responding and when a sensor goes out of range of a configurable threshold.
    • Alerts are posted in message log, which is accessible through Web user interface. The log can be downloaded as a tab-delimited plain text file.
Regulatory Approvals
  • CE, RoHS
Warranty
  • Two years
Example application of IPDU-S2

Control Methods

Web Interface (view product demo)
  • Configure, control and monitor via HTTP/HTTPS webpage.
  • Configure outlet operation settings, sensor thresholds and timing, circuit breaker settings, alarm methods, alert formats, sensor/IP device outlet association, and system data log.
  • View power outlet status, sensor values, IP device values, and alert status.
    • All connected power outlets, devices, and sensors can be viewed on one summary page.
    • View, Edit, Turn On/Off, Cycle buttons for each power outlet.
    • View and Edit sensors and IP devices.
  • View entries stored in the system logs.
    • Event log records system events such as alerts, user login/logout, failed email messages, etc.
    • Data log records samples of sensor readings. User specifies sampling time period.
    • The log can be downloaded as a tab-delimited plain text file.
  • Configure IP information (address, subnet mask, default gateway, DNS, etc.), SMTP settings, SNMP settings, IP filtering, and user administrative settings.
    • Administrator can restrict or grant access from certain IP addresses based on configured filter rules.
  • Administrate up to 15 users plus a root administrator.
  • Permissions, schedule and alert methods are configurable for each user.
RS232/Telnet/SSH
  • Configure, control and monitor over the text-based menu system accessible via RS232, Telnet, and SSH.
  • Access is controlled via username/password.
    • System stores encrypted login information.
  • Two user levels: User and Administrator.
Front Panel LED Indicators
  • "POWER" (green) — indicates device is powered.
  • "BREAKER" (red) — breaker has been tripped.
  • "OUTLET" (green / red) — outlet is on or off.
  • "SENSOR FAULT" (red) — lights up if a sensor goes out of range of a configurable threshold.
  • "IP FAULT" (red) — lights up if an IP device is unresponsive.
Network Operation
  • SNMP support, allowing integration into network management platforms.
Open Source Monitoring Integration

Security

  • Local DB or LDAP authentication
  • TLS/SSL secure communications
  • SSH v2
  • AES, 3DES/DES, Blowfish, RSA, EDH-RSA, Arcfour Encryptions
Secure Remote Power Rebooter Web Interface Screen Shot
Secure Remote Power Reboot Web Interface Screen Shot
Secure Remote Power Rebooter Text-based Menu Interface Screen Shot
Secure Remote Power Reboot Text-Based Menu Interface Screen Shot

Secure Remote Power Reboot Switch with Environmental Monitoring

NTI Part # # of Outputs Input Current Capacity Output Current Capacity
Dimensions WxDxH (in)
Dimensions WxDxH (mm)
# to Quote Power Cord Length
IPDU-S2 2 15A 10A
6.1x5.6x1.7
155x142x43
IPDU-S4 4 20A 15A
7x6x3.5
178x152x89
NA
IPDU-S4R 4 20A 15A
13.5x6x1.75 (without supplied rackmount kit)
19x6x1.75 (with supplied rackmount kit)
343x152x45 (without supplied rackmount kit)
483x152x45 (with supplied rackmount kit)
NA
IPDU-S8 8 20A 15A
17.4x6x1.75 (without supplied rackmount kit)
19x6x1.75 (with supplied rackmount kit)
442x153x45 (without supplied rackmount kit)
483x152x45 (with supplied rackmount kit)
NA

Sensors

NTI Part # Description # to Quote
ENVIROMUX-STS Temperature Sensor
ENVIROMUX-SHS Humidity Sensor
ENVIROMUX-STHS Temperature/Humidity Sensor
ENVIROMUX-STHS-99 Temperature/Wide Range Humidity Sensor
ENVIROMUX-LDTx-y Liquid Detection System

Select Length of Water Sensor Cable to Order (x):


Enter Length of 2-Wire Cable to Order (y):
(5 feet (1.5 meter) to 100 feet (30.5 meter).
Request Quote

Secure Remote Power Reboot Switch with Environmental Monitoring

NTI Part # # of Outputs Input Current Capacity Output Current Capacity Desktop Size (mm) Rackmount Size
IPDU-S2 2 15A 10A 155x142x43 NA
IPDU-S4 4 20A 15A 178x152x89 NA
IPDU-S4R 4 20A 15A 343x152x45
(without supplied rackmount kit)
483x152x45
(with supplied rackmount kit)
IPDU-S8 8 20A 15A 442x153x45
(without supplied rackmount kit)
483x152x45
(with supplied rackmount kit)

Sensors

NTI Part # Description
ENVIROMUX-STS Temperature Sensor
ENVIROMUX-SHS Humidity Sensor
ENVIROMUX-STHS Temperature/Humidity Sensor
ENVIROMUX-STHS-99 Temperature/Wide Range Humidity Sensor
ENVIROMUX-LDTx-y Liquid Detection System

Select Length of Water Sensor Cable to Order (x):

Enter Length of 2-Wire Cable to Order (y):